Operates up to 7 years without battery replacement

Ignores thunder, dogs barking and noise outside the window

Detects breakage at a distance of up to 9 m

Principle of operation

Detects broken glass using an electret microphone, which registers the sound of impact against the glass and of the glass falling.

Features

Two-factor detection of broken glass prevents false alarms caused by thunder, dogs barking and noise from passing trucks.

Installation and set up

Ready to operate straight out the box: the battery is already installed, therefore there is no need to disassemble the detector. With one click, it can be connected to the hub in the mobile application. It can be mounted on the SmartBracket in just a few minutes.

Tech specs

Classification

Surface sound radio channel security detector

Type of detector

Wireless

Installation method

Indoors

Compatibility

Operates with all Ajax hubs, range extenders, ocBridge Plus, uartBridge

Sensing element

Electret microphone

Break detection distance

Up to 9 m

Alarm signal delivery time

0.15 s

Sensitivity

Adjustable, 3 levels

Detection angle

180°

Power supply

Battery: CR123A battery, 3 V

Battery life

Up to 7 years

Jeweller radio technology

Communication range with central unit — up to 1,000 m in an open space
Two-way communication between devices
Operating frequencies — 866.0 – 866.6 MHz
Self-adjusting RF output power — up to 20 mW
Block encryption based on AES algorithm
Detector polling period — 12−300 s

Temperature sensor

Available

Operating temperature range

From -10°С to +40°С

Permissible humidity

Up to 75%

Anti-sabotage

Protection against fraud
Jamming detection
Tamper-resistant

Remote setting and testing

+

Dimensions

Diameter: 20 mm
Height: 90 mm

Weight

30 g

Warranty

Replacement and repair within 24 months of the date of sale. Batteries are not covered under warranty.

Complete set

GlassProtect glass break detector
SmartBracket mounting panel
CR123A battery (pre-installed)
External contact
Installation set
User’s guide